Product Overviews
The Manual Medical Manifold Gas Systems Oxygen Manifold Gas System can realize automatic switching without any adjustment by the operator, and it can still work normally even when the electrical system is powered off.
Features of Manual Medical Manifold Gas Systems Oxygen Manifold Gas System:
1. CE certification.
2, Automatic switching, strong and weak electricity separation.
3. On-site signal lights indicate working status, pressure gauges display pressure, with sound and light alarm function.
4. Secondary pressure regulator and pressure reducer for one backup and one use.
5. Continuous gas supply and automatic switching after power failure, it is not necessary to close the gas supply pipeline during maintenance.
6. Touch screen, PLC control.
7. With temperature control to prevent frost and overheating and leakage.
8. The pipeline adopts the form of live connection, which is more convenient for maintenance.
9. Reliable wall installation or horizontal installation.
10. Valves and pipes are made of 316L BA grade stainless steel, with high cleanliness.
11. Pilot-operated control switching gas path, pressure is stable.
Gas | Input Pressure mpa(psi) | Output Pressure mpa(psi) | Output Flow m3/h | Power |
O2 | 15(2175) | 0.07-1(10-145) | 100 | 220v, 50hz |
C2H2 | 3(435) | 0.01-0.1(1.5-15) | 20 | 220v, 50hz |
C3H8 | 3(435) | 0.03-0.85(4.4-125) | 60 | 220v, 50hz |
CO2 | 15(2175) | 0.03-0.85(4.4-125) | 60 | 220v, 50hz |
Ar | 15(2175) | 0.07-1.4(10-203) | 90 | 220v, 50hz |
He | 15(2175) | 0.07-1.4(10-203) | 250 | 220v, 50hz |
N2 | 15(2175) | 0.07-1.4(10-203) | 105 | 220v, 50hz |
Air | 15(2175) | 0.07-1.4(10-203) | 105 | 220v, 50hz |
N2O | 15(2175) | 0.07-1.4(10-203) | 60 | 220v, 50hz |
THE INTEGRATED SOLUTIONS FOR MEDICAL GAS SYSTEM
Medical gas four safety principles:
Continuous gas supply
Sufficient flow and pressure
Gas identification
Gas quality
Pipe Material | The main oxygen pipeline and the branch pipeline into the room are used of defatted purple copper tube or stainless steel tube. The pipeline inside of Bed Head Unit is using degreased copper pipe. | |
Pipe Setting | The gas riser pipe is designed in the pipeline well. Pipes should be piped when crossing the wall. The pipes installation should be neat and beautiful. |
Pipe Connection | Pipe system using welded connection. Metal seals throughout the pipe system connection Horizontal pipe and branch pipe of bed head unit should be with maintenance valve |
Pipe Grounding | Medical gas pipelines in medical rooms should be equipotential grounded; mainfold/pipelines etc should be anti-static grounded; Independent grounding resistance should less than 10Ω; |
Pipeline Leakage Rate | Leakage test of medical gas pipelines when no terminal components are connected, the hourly leakage rate should not exceed 0.05%. According to Chinese standard GB50751-2012 |